Micropolis hard Disk Drives, Specifications, Support, Specs, Jumpers, Manual, Images

Micropolis 1528-15

Hard Disk Drive

Overview

Model Capacity Size Height Interface Bus Type
Micropolis 1528-15 1342MB 5.25" FHT SE SCSI2

Specifications

Size 5-1/4"
Interface SCSI-2
Interface Type
Encoding Method RLL
Formatted Capacity 1342 MB
Disks 8
Heads 15
Cylinders 2100
Sectors 84
Buffer Size N/A
Average Seek 14.5 msec
Single Track 4 msec
Rotation Speed / Avg. Latency 3600 rpm +/- 0.5%
Transfer Rate to / from media 23.33 Mbits/sec
Transfer Rate to / from buffer N/A
Tracks Per Inch (TPI)
Bits Per Inch (BPI)
Dimensions 8.0"L x 5.75"W x 3.25"H
Weight 5.75 lbs.

Power Requirements

+12V +/-5% +5V +/-5% Power
Spin up 4.3A (max)
Read / Write 2.0A avg 1.5A avg
Typical 24 Watts

Notes

Drive Addressing and Interface Termination
 
              _ID2  
             |  _ID1  
             | |  _ID0  
             | | |                        Pin 1  
         J2  | | |              J1            |       J3   
      ___________    __________________________     ________  
    _|           |  |                          |   |        |  
   | |___________|_ |__________________________|___|________|  
   |  ..  ..                                                |  
   |  W5  W4          RN9         W2                        |  
   |                              W1                 W11    |  
   |                                                        |  
   |                                                    W28 |  
   |                                                        |  
   |                                                        |  
   |                                                        |  
   |                                                        |  
   |                                                        |  
   |                                 Component Side         |  
   |                                                        |  
 
 
ID0, ID1, ID2 SCSI Address Jumpers
  The SCSI ID (drive address) jumpers are identified as ID0, ID1,
and ID2. ID selection is binary, as shown in the table below.
SCSI
Address
Jumpers
ID2 ID1 ID0
0 out out out
1 out out in
2 out in out
3 out in in
4 in out out
5 in out in
6 in in out
7 in in in

  For multiple drive installations, on one Host Adapter, each drive must
  have a unique address. Drives are configured as SCSI ID 7 at the factory.

RN9 Interface Terminator
  The Interface Terminator factory installed at RN9 provides
  proper termination for the interface lines. When daisy-chaining
  multiple drives, leave the terminator installed only in the last
  physical drive (or drives) on the daisy chain cable; remove the
  terminator from each of the other drives (or the host computer).

W1, W2, Terminator Option
  W1 and W2 select the source of terminator power (+5V) for the
  interface terminator. If a jumper is installed at W1(the factory
  default configuration), and no jumper is installed at W2 the
  drive provides terminator power. This configuration is used
  for PC/AT applications. If a jumper is on W2 the host adapter
  will supply terminator power. If a jumper is installed at W2 and
  W11, and no jumper is installed at W1 the drive provides
  terminator power to it's on-board terminators and also to the
  SCSI bus via interface connector J1, pin 26.

W11 Bus Option
  W11 allows the drive to supply interface terminator power to the
  SCSI Bus. If W11 is not installed and W1 is jumpered (the factory
  default configuration), the drive does supply SCSI bus interface
  terminator power. W11 should not be installed for PC/AT
  applications.

W5 Spindle Option
  Selects the spindle control option. If W5 is jumpered, the
  drive must wait for a Start Spindle command (after power is
  applied) to start the spindle motor. If W5 is not installed
  (the factory default configuration), the drive automatically
  starts the spindle motor at power-on. W5 is not installed for
  PC/AT installations.

W4 Bus Parity Option
  W4 selects the parity check option. If W4 is installed, the drive
  neither generates nor detects parity. If W4 is not installed (the
  factory default configuration), the drive generates parity and
  enables parity detection. W4 is usually not installed for PC/AT
  applications. Verify the correct configuration required by your
  Host Adapter.

W28 Ground Options
  W28(only implemented on Rev B and later boards) is used to
  connect the drive's logic ground to frame ground. When at jumper
  is installed at W28, frame ground is connected to logic ground.

  When a jumper is not installed at W28 (the factory default
  configuration), frame ground is not connected to logic ground.
  For PC/AT applications, is a jumper should be installed at W28.


Also refer to the notes on installation in HP workstations or in workstations from Sun Microsystems. .