Micropolis hard Disk Drives, Specifications, Support, Specs, Jumpers, Manual, Images

Micropolis 1936-21

Hard Disk Drive

Overview

Model Capacity Size Height Interface Bus Type
Micropolis 1936-21 3022MB 5.25" FHT Fast SCSI2

Specifications

Size 5-1/4"
Interface SCSI-2F
Encoding Method
Formatted Capacity 3022 MB
Disks 11
Heads 21
Cylinders 2772
Sectors Variable
Buffer Size N/A
Average Seek 11.5 msec
Single Track 2.0 msec
Rotation Speed / Avg. Latency 5400 rpm +/- 0.5%
Transfer Rate to / from media 10 Mbytes / sec Synchronous
Transfer Rate to / from buffer N/A
Tracks Per Inch (TPI)
Bits Per Inch (BPI)
Dimensions 8.0"L x 5.75"W x 3. 25"H
Weight 5.75 lbs.

Power Requirements

+12V +/-5% +5V +/-5% Power
Spin up 1.95A
Read / Write 4.35A .9A
Typical 30 Watts

Notes

Drive Addressing and Interface Termination



ID0, ID1, ID2 SCSI Address Jumpers
  The SCSI ID (drive address) jumpers are identified as ID0, ID1, and ID2.
  ID selection is binary, as shown in the table below.

SCSI
Address
Jumpers
ID2 ID1 ID0
0 out out out
1 out out in
2 out in out
3 out in in
4 in out out
5 in out in
6 in in out
7 in in in

  For multiple drive installations, on one Host Adapter, each drive must
  have a unique address. Drives are configured as SCSI ID 7 at the factory.

RN4 & RN5 Interface Terminators
  The Interface Terminator factory installed at RN6 provides proper termination
  for the interface lines. When daisy-chaining multiple drives, leave the
  terminator installed only in the last physical drive (or drives) on the daisy
  chain cable; remove the terminator from each of the other drives (or the host computer).

Bus Termination Power Option
  A jumper is installed at W6, at W8, or at W5 to select the source of terminator
  power (+5V) for the SCSI Bus terminator packs on the device electronics board.

  When a jumper is installed at W6 (the factory default configuration), the drive
  provides terminator power to it's on-board terminators.

  When a jumper is installed at W8 , terminator power is is provided by the host
  system via the interface cable J1, pin 26 (TERMPWR).

  When a jumper is installed at both W8 and W5, the drive provides terminator
  power to its on-board terminators and also to the SCSI bus via interface cable J1,
  pin 26(TERMPWR).

Frame Ground Options
  Jumper W7 selects the frame ground option.

  When W7 is installed, the drive's frame is connected to frame ground.

  When a jumper is not installed at W7 (the factory default configuration),
  frame ground is not connected to logic ground.

Spindle Control Options
  A jumper bridging pins 7 and 8 of J2 (the 4th set of pins) is used to select
  the spindle control option.

  When a jumper is installed, the drive must wait for an interface Start Unit
  command to start the spindle motor.

  When a jumper is not installed (the factory default configuration), the drive
  automatically starts the spindle motor at power-on.

SCSI-1/2 Select
  A jumper at WP selects SCSI-1 or SCSI-2. If the jumper is installed
  (the factory default configuration), the drive is configured as a SCSI-2 device.
  the drive is not write protected.

Bus Parity Option
  A jumper bridging pins 13 and 14 of J2(7th set of pins) is used to select the
  parity check option.

  When a jumper is not installed, (the factory default configuration), the drive
  generates parity and enables parity detection.

  When a jumper is installed, the drive neither generates nor detects parity.

Spindle Synchronization Option
  The Rotational Position Locking field (MODE SELECT command, Page Code 04h)
  is used to specify spindle synchronization operation; see document #110366
  (Scsi Implementation in Micropolis "MZR" Products) and ANSI SCSI Standard.

  Unsynchronized: If the drive is set to Unsynchronized (PRL=00b), it ignores the
  SLAVE SYNC signal.

  Slave: If the drive is set to Slave (RPL=01b), it does not generate the MASTER SYNC
  signal or the SLAVE SYNC signal but synchronizes its index to the SLAVE SYNC
  signal (J2,pin 20) supplied by an external source.

  Master: If the drive is set to MASTER (RPL=10b), it generates the SLAVE SYNC
  output signal (j2,pin 20) for use directly by the slave drives.

  Master Control: If the drive is set to Master Control (RPL=11b), it generates the
  MASTER SYNC signal (j2,pin 20). This output is used by the controller to generate
  the SLAVE SYNC signal(J2,pin 20) for the slave drives.