Hard Disk Drive
Model | Capacity | Size | Height | Interface | Bus Type |
---|---|---|---|---|---|
Micropolis 4421AV Aries 2 | 2050MB | 3.5" | SL | Fast | SCSI2 |
Size | 3 1/2" |
Interface | SCSI-2 |
Interface Type | Narrow, Single-Ended |
Encoding Method | |
Formatted Capacity | 2050 MB |
Disks | 5 |
Heads | 9 |
Cylinders | 4050 |
Sectors | Variable |
Buffer Size | N/A |
Average Seek | 8.8 msec |
Single Track | |
Rotation Speed/Avg. Latency | 5400 rpm +/- 0.5% |
Transfer Rate to / from. media | 20 Mbytes/sec Synchronous |
Transfer Rate to / from buffer | |
Tracks Per Inch (TPI) | |
Bits Per Inch (BPI) | |
Dimensions | 5.75"D x 4.0"W x 1.0"H |
Weight | 0.00 lbs. |
+12V +/-5% | +5V +/-5% | Power | |
Spin up | .55A | ||
Read / Write | 1.75A | 1.1A | |
Typical seeking | 12 Watts |
Notes: | |||||||||||||||||||||||||||||||||||||||
Remote LED Open-collector output - Used to drive a user-supplied LED to indicate the drive is active. SCSI Address (ID0, ID1, and ID2) Jumpers ID0, ID1, and ID2 select the SCSI address. Each SCSI device on one Host Adapter must have a unique address. SCSI ID0 is Default.
Terminator Power (W1, W2, W3) Jumper installed at W1 (Default) - The disk drive provides terminator power. Jumper installed at W2 - The host provides terminator power via interface connector J1. Jumper installed at W3 (Default) - The disk drive provides terminator power to the SCSI Bus via interface connector J1. Interface Termination (W4) Jumper installed at W4 (Default) - The disk drive is terminated; i.e., onboard termination is electrically enabled. Jumper omitted at W4 - The disk drive is not terminated; i.e., onboard termination is electrically disabled. Spindle Control (SP0) Jumper installed at SP0, jumper omitted at SP1 - The spindle motor starts when SCSI �START UNIT� command is received. Jumpers omitted at SP0 (Default) and at SP1 - The spindle motor starts at power-on. Spindle Delay (SP1) Jumper installed at SP1, jumper omitted at SP0 - The spindle motor start-up delayed based on SCSI ID (12 seconds per SCSI ID). Jumpers omitted at SP1 (Default) and at SP0 - The spindle motor starts at power-on. Write Protect (WP) Jumper installed at WP - The disk drive is write protected. Jumper omitted at WP (Default) - The disk drive is not write protected. BUS Parity Check (PTY) Jumper installed at PTY - The disk drive neither generates nor detects parity. Jumper omitted at PTY (Default) - The disk drive generates parity and has parity detection enabled. |